| Sign In | Join Free | My chinabagsnet.com | 
 | 
Brand Name : PANRAN
Model Number : PR231
Certification : CE,ISO9001
Place of Origin : Tai'an,China
MOQ : 1 pcs
Price : negotiable
Payment Terms : TT, LC, Visa, Western Union, Alipay, Trade assurance, E-checking
Supply Ability : 20 pcs / month
Delivery Time : 15~25 working days
Packaging Details : Standard export Packing (aluminium alloy, laminated wood, carton)
Cell type : 7.4V 4400mAh, Rechargeable lithium battery
Preheating time : 10 minutes after preheating
Charging time : 5 hours
charging source : 100~240V AC,50~60Hz
Working temperature : -10℃~50℃
Working time : ≥20 hours(24V power off)
Humidity : 0~80%,Non condensing
Calibration period : 2 years
Size : 225mm*130mm*53mm
Weight : 990g
parameters of measurement : Voltage,Current,Ohm,Thermal couple,Cold end compensation,Thermal resistance,Standard temperature,ρ-value,Frequency,Temperature difference
parameters of the output function : Voltage,Current,Ohm,Thermal couple,Thermal resistance,Frequency / Pulse,Precision temperature control,24V output

1. Temperature difference measurement with accuracy of 0.003 ° C
PR231A calibrator measures the temperature difference between two points in space without other instruments. When the function is used, the four terminals of the source function be used as measurement terminals and the process of the temperature difference data acqusition can be completed within 0.4 Seconds, which effectively improves the accuracy of
the measurement. The stability can also be calculated in real time during the test

2.Standard temperature measurement
Different from ordinary TC and RTD measurement, the standard temperature measurement may use the certificate value for temperature traceability. The input signals include:STC - > S type, R type, B type, T type.SPRT-> Rtp = 25Ω or Rtp=100Ω.

3.Reference Junction Compensation
The reference junction compensation methods of the PR231 series calibrator are very flexible and three methods are available, namely internal, external, and customized. The external reference junction adopts Grade A Pt100, and can input the certificate value for the reference junction data correction. When PR231 series calibrator is combined with PR1501 temperature equalization compensation module, a reference junction compensation error of less than 0.07°C can be obtained.

4.Precision temperature control function
Using the precision temperature control function, temperature closed-loop control of the constant temperature equipment can be realized instead of the high-precision PID controller. In the case that the constant temperature equipment and grid voltage are satisfactory to the conditions, the temperature fluctuation of the equipment can be better than 0.02°C /10min (thermostatic bath).
5.ρvalue measurement
The PR231 series calibrator can measure the duty factor of the periodic square signal and can be used to verify and calibrate the PID parameters of various digital temperature indicating regulators for time proportional output, and meet the requirements of JJG 617-1996 Verification Regulation of Digital Temperature Indicators and Controllers.
6.Thermal calculator
It is used to achieve various conversions between electric and temperature. The conversion support a variety of TCs, RTDs and thermistors.
7. Value Settings
The PR231 series calibrator has the most flexible and convenient output value setting method. It is possible to directly set the output value through the numeric keypad, or to increase the increment setting by pressing the direction key. In addition, the device has an editable phase step or slope value setting method.
8.Sinusoidal signal output function
The verification/calibration of some process loggers, especially mechanical recorders, usually involves the operation test. In this case, the user can use the device's sinusoidal signal output function to provide signals for the verified instrument.

The verification/calibration of some process recorders (especially mechanical recorders) usually involves the operation of the test. At this time, the device's sinusoidal signal output function can be used to signal the meter.
9.Data logging function
The logging function saves measurement and output data. PR231 series calibrator has powerful record management functions. Up to 32 device numbers can be created. Each device number has 16 logging pages. Each logging page contains four kinds of basic information, namely time, measured value, output value and custom value. Basic information. Users can perform device processing, record deletion, etc. according to their needs.
• Automatic protection in case of 220V wrong connection in any probes.
 • DC mV output and simulation of thermocouple output.
 • Thermocouple(TC) measurement provides cold-junction compensation.
 • Manual stepping, automatic stepping, 0~100% phase step and slope output
 • Have manual and automatic cold junction compensation when measuring and simulating thermocouple signal.
 • Support 6 units AAA dry battery power supply, easy to use.
 • An ideal replacement model of Fluke 714 temperature calibrator.
| Item | PR231A-1 | PR231A-2 | PR231B-1 | PR231B-2 | 
| Enhancement model |  |  | ||
| Basic model |  |  | ||
| 0.01 grade |  |  | ||
| 0.02 grade |  |  | 
| Weight | 990g | charging source | 100~240V AC,50~60Hz | 
| Dimension | 225mm*130mm*53mm | Working temperature | -10℃~50℃ | 
| Cell type | 7.4V 4400mAh, Rechargeable lithium battery | Working time | ≥20 hours(24V power off) | 
| Preheating time | 10 minutes after preheating | Humidity | 0~80%,Non condensing | 
| Charging time | 5 hours | Calibration period | 2 years | 
1. Basic parameters of measurement:
| Function | Range | Measurement range | Resolution | 0.01 accuracy | 0.02 accuracy | Remarks | 
| Voltage | 100mV | -5mV~120mV | 0.1uV | 0.005%RD+5uV | 0.015%RD+ 5uV | Input impedance ≥80mΩ | 
| 1V | -50mV~1.2V | 1uV | 0.005%RD+ 0.005%FS | 0.015%RD+ 0.005%FS | ||
| 10V | -0.5V~12V | 10uV | Input impedance ≥1mΩ | |||
| 50V | -0.5V~50V | 0.1mV | ||||
| Current | 50mA | -5mA~50 mA | 0.1uA | 0.005%RD+0.005%FS | 0.015%RD+ 0.005%FS | Internal resistance =10Ω | 
| Ohm | 50Ω | 0Ω~50Ω | 0.1mΩ | 0.005%RD+5mΩ | 0.015%RD+ 5mΩ | Output 1mA current | 
| 500Ω | 0Ω~500Ω | 1mΩ | 0.005%RD+0.005%FS | 0.015%RD+ 0.005%FS | ||
| 5kΩ | 0kΩ~5kΩ | 10mΩ | Output 0.1mA current | |||
| Thermal couple | S,R,B,K,N,J,E,T,EA2,Wre3-25,Wre5-26 | 0.1℃ | / | According to ITS-90 scale | ||
| Cold end compensation | Internal | -10℃~60℃ | 0.01℃ | 0.5℃ | 0.5℃ | |
| External | 0.1℃ | 0.1℃ | ||||
| Thermal resistance | Pt10,Pt100, Pt200,Cu50,Cu100,BA1,BA2,JPt100, Pt500, Pt1000 | 0.01℃ | / | |||
| Standard temperature | S,R,B,T,SPt25,SPt100 | 0.01℃ | / | Need to enter the correction value | ||
| ρ-value | 50S | 0.001%~99.999% | 0.001% | 0.005% | 0.005% | Input pulse width amplitude range:1V~50V | 
| Frequency | 10Hz | 0.001Hz~12Hz | 0.001Hz | 0.01%FS | 0.01%FS | |
| 1kHz | 0.00001kHz~ 1.2 kHz | 0.01Hz | ||||
| 100kHz | 0.01kHz~ 120 kHz | 10Hz | 0.1%FS | 0.1%FS | ||
| Temperature difference | S,R,B,K,N,J,E,T | 0.01℃ | / | Need to enter the correction value | ||
| SPt25,SPt100 | 0.001℃ | |||||
2. Basic parameters of the output function:
| Function | Range | Measurement range | Resolution | 0.01 accuracy | 0.02 accuracy | Remarks | 
| Voltage | 100mV | -20mV~120mV | 1uV | 0.005%RD+5uV | 0.015%RD+5uV | Maximum load current =2.5mA | 
| 1V | -0.2mV~1.2V | 10uV | 0.005%RD+0.005%FS | 0.015%RD+0.005%FS | ||
| 10V | -2V~12V | 0.1mV | ||||
| Current | 30mA | -5mA~30 mA | 1uA | 0.005%RD+0.005%FS | 0.015%RD+0.005%FS | Maximum load voltage =24V | 
| Ohm | 50Ω | 0Ω~50Ω | 0.1mΩ | / | According to ITS-90 scale | |
| 500Ω | 0Ω~500Ω | 1mΩ | ||||
| 5kΩ | 0kΩ~5kΩ | 10mΩ | ||||
| Thermal couple | S,R,B,K,N,J,E,T,EA2,Wre3-25,Wre5-26 | 0.1℃ | / | |||
| Thermal resistance | Pt10,Pt100, Pt200,Cu50,Cu100,BA1,BA2,JPt100, Pt500, Pt1000 | 0.01℃ | / | |||
| Frequency / Pulse | 10Hz | 0.001Hz~ 12 Hz | 0.001Hz | 0.01%FS | 0.01%FS | Maximum load current =2.5mA | 
| 1kHz | 0.00001kHz~ 1.2 kHz | 
 0.01Hz | ||||
| 100kHz | 0.01kHz~120 kHz | 10Hz | 0.1%FS | 0.1%FS | ||
| Precision temperature control | S,R,B,K,N,J,E,T | 0.01℃ | / | |||
| Pt100 | ||||||
| 24V output | Maximum voltage error: 0.3V Ripple noise:35mVp-p(20MHz bandwidth) Maximum load current:70mA Load regulation: 0.5%(10% -100% load change) | |||||


1. Measuring function terminal area (withstand 100V DC voltage input error)
2. Output function terminal area(withstand 36V DC voltage input error)
3. Dust cover
4. Side band(length adjustable )
5. Holder
6. External Pt100 Reference point sensor interface
7. USB2.0 communication interface
8. Multi-function port (With RS232 communication, USB communication, isolated 24V voltage output, precision temperature control signal output, pressure calibration, and other functions)
9. Reset
10. Supply hub(Connect the external AC power adapter)
11. Equipment nameplate
12. Battery
13.Protective tube
14.Screen contrast adjusting knob
15.Battery port
a.Adjust length here
b.Unfold jacket toward this direction
c. Holder unfold direction
|   | 
| Rechargeable PANRAN PR231 Series Thermocouple Calibrators Images | 
 Portable 4400mAh 100V AC Thermocouple Calibrators
                                                                                    
                        
                        
                        
                                                            Portable 4400mAh 100V AC Thermocouple Calibrators
                                                    
                        
                     High Precision ±0.003 ° C Temperature Transmitter Calibration
                                                                                    
                        
                        
                        
                                                            High Precision ±0.003 ° C Temperature Transmitter Calibration
                                                    
                        
                     7.4V 990g Thermocouple Calibrators For Transmitters
                                                                                    
                        
                        
                        
                                                            7.4V 990g Thermocouple Calibrators For Transmitters
                                                    
                        
                     ISO9001 Reliable Streamline Handheld Temperature Calibrator
                                                                                    
                        
                        
                        
                                                            ISO9001 Reliable Streamline Handheld Temperature Calibrator
                                                    
                        
                     Standard Rechargeable ISO9001 Thermocouple Calibrators
                                                                                    
                        
                        
                        
                                                            Standard Rechargeable ISO9001 Thermocouple Calibrators
                                                    
                        
                     Electrical 7.4V 4400mAh Portable Temperature Calibrator
                                                                                    
                        
                        
                        
                                                            Electrical 7.4V 4400mAh Portable Temperature Calibrator
                                                    
                        
                     Multifunctional 240V AC Thermocouple Calibrators
                                                                                    
                        
                        
                        
                                                            Multifunctional 240V AC Thermocouple Calibrators
                                                    
                        
                     240V AC Thermocouple Calibrators
                                                                                    
                        
                        
                        
                                                            240V AC Thermocouple Calibrators
                                                    
                        
                     RTD Types Thermocouple Calibrators
                                                                                    
                        
                        
                        
                                                            RTD Types Thermocouple Calibrators
                                                    
                        
                     Rechargeable Handheld Temperature Calibrator
                                                                                    
                        
                        
                        
                                                            Rechargeable Handheld Temperature Calibrator